Lateef A. Z. Q. 
Development of 3D environmental laser scanner using pinhole projection / A. Z. Q. Lateef // Вост.-Европ. журн. передовых технологий. - 2021. - № 2/1. - С. 37-43. - Бібліогр.: 45 назв. - англ.

Three-dimensional (3D) information of capturing and reconstructing an object existing in its environment is a big challenge. In this work, we discuss the 3D laser scanning techniques, which can obtain a high density of data points by an accurate and fast method. This work considers the previous developments in this area to propose a developed cost-effective system based on pinhole projection concept and commercial hardware components taking into account the current achieved accuracy. A laser line auto-scanning system was designed to perform close-range 3D reconstructions for home/office objects with high accuracy and resolution. The system changes the laser plane direction with a microcontroller to perform automatic scanning and obtain continuous laser strips for objects' 3D reconstruction. The system parameters were calibrated with Matlab's built-in camera calibration toolbox to find camera focal length and optical center constraints. The pinhole projection equation was defined to optimize the prototype rotating axis equation. The developed 3D environmental laser scanner with pinhole projection proved the system's effectiveness on close-range stationary objects with high resolution and accuracy with a measurement error in the range (0,05 - 0,25) mm. The 3D point cloud processing of the Matlab computer vision toolbox has been employed to show the 3D object reconstruction and to perform the camera calibration, which improves efficiency and highly simplifies the calibration method. The calibration error is the main error source in the measurements, and the errors of the actual measurement are found to be influenced by several environmental parameters. The presented platform can be equipped with a system of lower power consumption, and compact smaller size.


Індекс рубрикатора НБУВ: Д104

Рубрики:

Шифр НБУВ: Ж24320 Пошук видання у каталогах НБУВ 
Повний текст  Наукова періодика України 
  Якщо, ви не знайшли інформацію про автора(ів) публікації, маєте бажання виправити або відобразити більш докладну інформацію про науковців України запрошуємо заповнити "Анкету науковця"
 
Національна бібліотека України імені В. І. Вернадського
Відділ наукового формування національних реферативних ресурсів
Інститут проблем реєстрації інформації НАН України

Всі права захищені © Національна бібліотека України імені В. І. Вернадського